Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Fast and fantastic quotations, informed advisers to help you choose the correct products that suits all your needs, a short manufacturing time, responsible good quality control and distinct companies for paying and shipping affairs for Rack Condensing Unit, Commercial Supermarket Refrigerators, Air-Cooled Condensing Unit, Our company eagerly looks forward to establishing long-term and friendly business partner relationships with clients and businessmen from all over the world.
Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte Detail:

Parameter

Commercial hot water (1) Commercial hot water (2) Commercial hot water (3) Commercial hot water (4)

Unit Parameter Table
Air-cooled Module Unit Parameter Table
                                    Unit Type
Unit parameters
ZGR-65ⅡAG2 ZGR-130ⅡAG2
Rated Refrigeration
(A35/W7℃)
Cooling Capacity(kW) 65 130
Power(kW) 20.3 40.6
EER 3.20 3.20
Rated Heating
(A7/W45℃)
Heating Capacity(kW) 70 140
Power(kW) 20.5 41.0
COP 3.41 3.41
Mains 380V/3N~/50Hz
Maximum Operating Current(A) 58 115
Cooling Operating Ambient Temperature Range(℃) 16~49
Heating Operating Ambient Temperature Range(℃)  -15~28
Cooling Water Temperature(℃) 5~25
Heating Water Temperature(℃) 30~50
Refrigerant R410A
Safeguard Higher-lower voltage protection, antifreeze protection, overload, water flow protection, etc.
Capacity Adjustment Method 0~100% 0~50%~100%
Throttling Method Electronic Expansion Valve
Water Side Heat Exchanger Shell and Tube Heat Exchanger
Wind Side Heat Exchanger High-efficiency Finned Tube Heat Exchanger
Fan High Efficiency and Low Noise Axial Flow Fan
Water System Chilled Water Flow(m³/h) 11.2 22.4
Hydraulic Pressure Drop(kpa) 40 75
Maximum Working Pressure(Mpa) 1.0
Water Pipe Connection DN65(Flange) DN80(Flange)
Anti-shock Protection Type
Waterproof Level IPX4
Dimentions Length(mm) 1930 2340
Width(mm) 941 1500
Height(mm) 2135 2350
Weight(kg) 590 1000
Rated refrigeration: outdoor dry/wet bulb temperature is 35°C/24°C; outlet water temperature: 7°C
Rated heating: outdoor dry/wet bulb temperature is 7℃/6℃; outlet water temperature is: 45℃
Models, parameters, and performance will be changed due to product improvements. Please refer to the actual product and nameplate for specific parameters;
Executive Standard:GB/T 18430.1(2)-2007 GB/T 25127.1(2)-2010

Commercial hot water (6) Commercial hot water (7) Commercial hot water (8) Commercial hot water (9) Commercial hot water (10) Commercial hot water (11) Commercial hot water (12) Commercial hot water (13) Commercial hot water (14) Commercial hot water (15) Commercial hot water (16) Commercial hot water (17)


Product detail pictures:

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures

Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte detail pictures


Related Product Guide:

We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for Factory Free sample Vertical Condensing Unit - Heat pump water heater 20KW 30KW 40KW 60KW Geothermal ground source Heat Pump – Runte , The product will supply to all over the world, such as: Denmark, Wellington, Pakistan, Custom orders are acceptable with different quality grade and customer's especial design. We are looking forward to establish the good and successful cooperation in business with long terms from the customers of all over the world.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Maggie from California - 2017.06.29 18:55
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Daisy from Ottawa - 2018.09.29 17:23
    Write your message here and send it to us